Model: UC300-F43-2KIR2-V17Twin-head systemSensing range 0 ... 300 mmDead band 0 mmStandard target plate 100 mm x 100 mmTransducer frequency approx. 390 kHzResponse delay minimum (EM; NONE): ≤20 ms (2 measuring cycles)factory setting (EM, MXN, 5, 2): ≤60 ms (6 measuring cycles)dynamic (EM,DYN): ≤30 ms (3 measuring cycles)Operating voltage 10 ... 30 V DCripple ± 10 %SSInterface type RS 232, 9600 bit/s, no parity, 8 data bits, 1 stop bitOutput type 2 relay outputs, 1 analog output 4 ... 20 mAResolution 0.2 mmDeviation of the characteristic curve < 0.2 % of full-scale valueRepeat accuracy ≤ 0.1 % of full-scale valueRang
E Hysteresis 0 ... 15 % programmable with ULTRA 2001Load impedance current output:≤ 500 Ω at UB ≥ 17V≤ 200 Ω at UB < 17VContact loading 60 V DC/1 A (max. 24 W DC), ohmicLife span electrical: 3 x 105 switching cycles at resistive load(1 A / 24 V DC)mechanical: 107 switching cyclesAmbient temperature 0 ... 70 °C (32 ... 158 °F)Connection type Connector M12 x 1 , 8-pinscreen connected to pin 8Degree of protection IP65Material Housing PBTTransducer epoxy resin/hollow glass sphere mixture; polyurethane foam.